From T&A Valve
Industries THE TOTAL SOURCE!
 |
 |
|
SPENCE
Pilot Operated Regulators for Commercial & Industrial
Applications |
|
Widest choice
of pilots to suit many more challenging
applications. |
The
Spence Pilot Operated Regulator has been the
trouble-free standard for Commercial/HVAC
applications for nearly a century. What many people
don't know is that this same dependable, rugged
valve can provide these benefits in many Industrial
applications. If you are controlling s temperature,
pressure, back pressure or differential pressure
with a control valve and are plagued with erratic
control, poor or slow response, leaky valves and/or
complicated support systems, a Spence Pilot Operated
Regulator is often the solution. We have specialized
valve/pilot combinations to perform many tasks
traditionally done by control valves - without
typical control valve problems! |
 |
|
Main
Valves |
 |
|
Pressure Pilots |
|
 |
|
|
The right
choice in over 85% of pressure reduction
applications |
|
|
Add Type M
Pilot for electric on/off remote control |
|
|
Add Type D208
Pilot for automated station startup and shutdown |
|
|
Four pilots
with nine spring pressure ranges
from 15 inches vacuum to 350 psi |
|
A
AIR ADJUSTED PRESSURE REDUCING |
|
|
Pneumatic
remote adjustment |
|
|
Add Type P60
Pneumatic Controller for automatic control |
|
|
Eleven pilots
from 30 inches vacuum to 150 psi |
|
|
Quickly shuts
off flow when overpressure condition exists |
|
|
Four spring
pressure ranges from 5 to 175 psi |
|
|
Controls
system pressure above or below another process
variable |
|
|
Accurate
within ±1 psi |
|
|
Three pilots
with four spring pressure ranges from 3 to 150
psi |
|
|
Controls high
differential pressures in steam driven pumps |
|
|
Maintain an
average discharge pressure regardless of load
changes |
|
|
Five pilots
with 10 spring pressure ranges from 30 inches
vacuum to 2000 psi |
|
|
|
Maintains
constant adjustable initial pressure and
responds rapidly to sudden load changes,
preventing overpressure |
|
|
Three pilots
with seven spring pressure ranges from 1 to 350
psi |
|
|
Prioritizes
load allocation when system demand exceeds
supply |
|
|
Add Type D or
A Pilot to also control downstream pressure |
|
|
Four F Series
pilots with nine spring pressure ranges from 2
to 2000 psi |
|
|
Modulates a
process variable in relation to a proportional
electronic control input signal |
|
|
Permits
interfacing with Energy Management Systems |
|
|
Accepts 4-20,
10-50 and 1-5 mA input signals |
|
|
Emergency
control when low pressure valve fails in two
stage pressure reducing station where a safety
relief valve is not an option |
|
|
Typically used
with Type D or A Pilot |
|
|
Five spring
pressure ranges from 5 to 175 psi |
|
 |
 |
 |
 |
 |
 |
|
ED208D |
E5M33N |
EA
with A Panel |
ED |
EM33D-EZ |
|
|
|